blog:2020-04-12:power_cable_resistance
Differences
This shows you the differences between two versions of the page.
| Next revision | Previous revision | ||
| blog:2020-04-12:power_cable_resistance [2020/04/12 23:14] – created va7fi | blog:2020-04-12:power_cable_resistance [2020/08/07 13:03] (current) – external edit 127.0.0.1 | ||
|---|---|---|---|
| Line 1: | Line 1: | ||
| + | ====== Power Cable Resistance ====== | ||
| + | |||
| + | At home, my radio station is all crammed in a very tight space so the main battery bank is in a detached container about 55 ft away. A few weeks ago, I purchased a [[blog/ | ||
| + | |||
| + | {{ : | ||
| + | |||
| + | To quantify the voltage drop, I recorded the current draw, the voltage at the house, and the voltage at the container during six short transmissions at different power levels: | ||
| + | |||
| + | <WRAP indent> | ||
| + | |<10px >| | ||
| + | ^ ^Current (A) ^ House Voltage ^Container Voltage | | ||
| + | |No Tx |8.2 |12.9 |13.3 | | ||
| + | |5W | ||
| + | |12W |13.5 |12.1 |13.2 | | ||
| + | |25W |14.0 |11.9 |13.1 | | ||
| + | |50W |16.7 |11.6 |13.1 | | ||
| + | |100W | ||
| + | |> | ||
| + | </ | ||
| + | |||
| + | The first line (8.2 A) is the baseline when the radio was not transmitting (I have two computers running, an ethernet switch, and two radios monitoring). | ||
| + | |||
| + | Taking the difference between the currents during transmit and the baseline current of 8.2A, and the difference between the container voltage and the house voltage, I get the voltage drop in the cable as a function of the current: | ||
| + | |||
| + | {{ : | ||
| + | <WRAP indent> | ||
| + | |<10px >| | ||
| + | ^ ^Current (A) ^Voltage Drop (V) ^Power Loss (W) | | ||
| + | |5W | ||
| + | |12W |5.3 |1.1 |5.8 | | ||
| + | |25W |5.9 |1.2 |7.0 | | ||
| + | |50W |8.5 |1.5 |13 | | ||
| + | |100W | ||
| + | |> | ||
| + | </ | ||
| + | |||
| + | The slope of the line is the resistance since: \$R = \frac{\Delta V}{\Delta I}\$, which in my case is 0.09 Ω. Note also how much power is loss in the cable. | ||
| + | |||
| + | A trick to help reduce this power loss is to add a smaller battery in the house. | ||
| + | |||
| + | <WRAP indent> | ||
| + | |<10px >| | ||
| + | ^ ^Current (A) ^Voltage Drop (V) ^Power Loss (W) | | ||
| + | |5W |2.8 |0.5 |1.4 | | ||
| + | |12W | ||
| + | |25W | ||
| + | |50W | ||
| + | |100W |10.8 |0.7 |7.5 | | ||
| + | |>100W |16.7 |0.8 | ||
| + | </ | ||
| + | |||
| + | |||